Michael Figl

Orcid: 0000-0002-1745-0871

According to our database1, Michael Figl authored at least 59 papers between 2000 and 2020.

Collaborative distances:
  • Dijkstra number2 of five.
  • Erdős number3 of four.

Timeline

Legend:

Book 
In proceedings 
Article 
PhD thesis 
Dataset
Other 

Links

Online presence:

On csauthors.net:

Bibliography

2020
Error analysis for a navigation system using 3D abdominal ultrasound.
Proceedings of the Medical Imaging 2020: Image-Guided Procedures, 2020

2019
Design, Implementation, and Evaluation of a Head and Neck MRI RF Array Integrated with a 511 keV Transmission Source for Attenuation Correction in PET/MR.
Sensors, 2019

2017
Ultrasound guidance system for prostate biopsy.
Proceedings of the Medical Imaging 2017: Image-Guided Procedures, 2017

2016
New conversion factors between human and automatic readouts of the CDMAM phantom for CR systems.
Proceedings of the Medical Imaging 2016: Image Perception, Observer Performance, and Technology Assessment, San Diego, California, United States, 27 February, 2016

2014
SPECT-US image fusion and clinical applications.
Proceedings of the Medical Imaging 2014: Image-Guided Procedures, 2014

2013
An error analysis perspective for patient alignment systems.
Int. J. Comput. Assist. Radiol. Surg., 2013

Evaluation of three 3D US calibration methods.
Proceedings of the Medical Imaging 2013: Image-Guided Procedures, 2013

Image guidance system for flexible endoscopes considering tissue deformation.
Proceedings of the Medical Imaging 2013: Image-Guided Procedures, 2013

2012
Reconstruction of a 3D surface from video that is robust to missing data and outliers: Application to minimally invasive surgery using stereo and mono endoscopes.
Medical Image Anal., 2012

Real-time 2D/3D registration for tumor motion tracking during radiotherapy.
Proceedings of the Medical Imaging 2012: Image Processing, 2012

Automatic analysis of ciliary beat frequency using optical flow.
Proceedings of the Medical Imaging 2012: Image Processing, 2012

Automatic patient alignment for prostate radiation applying 3D ultrasound.
Proceedings of the Medical Imaging 2012: Image-Guided Procedures, 2012

Real-Time Intensity Based 2D/3D Registration for Tumor Motion Tracking During Radiotherapy.
Proceedings of the Bildverarbeitung für die Medizin 2012 - Algorithmen - Systeme, 2012

2011
Comparison of two navigation system designs for flexible endoscopes using abdominal 3D ultrasound.
Proceedings of the Medical Imaging 2011: Visualization, 2011

2010
Image guidance for robotic minimally invasive coronary artery bypass.
Comput. Medical Imaging Graph., 2010

Splint deformation measurement: a contribution to quality control in computer assisted surgery.
Proceedings of the Medical Imaging 2010: Visualization, 2010

A new gold-standard dataset for 2D/3D image registration evaluation.
Proceedings of the Medical Imaging 2010: Visualization, 2010

Towards real-time 2D/3D registration for organ motion monitoring in image-guided radiation therapy.
Proceedings of the Medical Imaging 2010: Visualization, 2010

A comment on the rank correlation merit function for 2D/3D registration.
Proceedings of the Medical Imaging 2010: Visualization, 2010

Measurement of complex joint trajectories using slice-to-volume 2D/3D registration and cine MR.
Proceedings of the Medical Imaging 2010: Visualization, 2010

Correction of prostate misalignment in radiation therapy using US-CT registration.
Proceedings of the Medical Imaging 2010: Visualization, 2010

A Robust Mosaicing Method with Super-Resolution for Optical Medical Images.
Proceedings of the Medical Imaging and Augmented Reality - 5th International Workshop, 2010

A Robust Mosaicing Method for Robotic Assisted Minimally Invasive Surgery.
Proceedings of the ICINCO 2010, 2010

2009
Evaluation of dynamic electromagnetic tracking deviation.
Proceedings of the Medical Imaging 2009: Visualization, 2009

Photo-consistency registration of a 4D cardiac motion model to endoscopic video for image guidance of robotic coronary artery bypass.
Proceedings of the Medical Imaging 2009: Visualization, 2009

Non-rigid Reconstruction of the Beating Heart Surface for Minimally Invasive Cardiac Surgery.
Proceedings of the Medical Image Computing and Computer-Assisted Intervention, 2009

2008
Augmented reality image guidance for minimally invasive coronary artery bypass.
Proceedings of the Medical Imaging 2008: Visualization, 2008

Sample Sufficiency and Number of Modes to Retain in Statistical Shape Modelling.
Proceedings of the Medical Image Computing and Computer-Assisted Intervention, 2008

A Novel Algorithm for Heart Motion Analysis Based on Geometric Constraints.
Proceedings of the Medical Image Computing and Computer-Assisted Intervention, 2008

Coronary Motion Modelling for Augmented Reality Guidance of Endoscopic Coronary Artery Bypass.
Proceedings of the Biomedical Simulation, 4th International Symposium, 2008

Sample Sufficiency and PCA Dimension for Statistical Shape Models.
Proceedings of the Computer Vision, 2008

Statistical shape modelling: How many modes should be retained?
Proceedings of the IEEE Conference on Computer Vision and Pattern Recognition, 2008

2007
Motion correction for radiation therapy of prostate using B-mode ultrasound.
Proceedings of the Medical Imaging 2007: Visualization and Image-Guided Procedures, 2007

Stochastic rank correlation for slice-to-volume registration of fluoroCT/CT imaging.
Proceedings of the Medical Imaging 2007: Visualization and Image-Guided Procedures, 2007

3D Reconstruction of Internal Organ Surfaces for Minimal Invasive Surgery.
Proceedings of the Medical Image Computing and Computer-Assisted Intervention - MICCAI 2007, 10th International Conference, Brisbane, Australia, October 29, 2007

2006
Endoscopic navigation system using 2D/3D registration.
Proceedings of the Medical Imaging 2006: Visualization, 2006

2005
A fully automated calibration method for an optical see-through head-mounted operating microscope with variable zoom and focus.
IEEE Trans. Medical Imaging, 2005

Standardized evaluation method for electromagnetic tracking systems.
Proceedings of the Medical Imaging 2005: Visualization, 2005

Design and automatic calibration of a head mounted operating binocular for augmented reality applications in computer-aided surgery.
Proceedings of the Medical Imaging 2005: Visualization, 2005

Fast DRR Generation for 2D/3D Registration.
Proceedings of the Medical Image Computing and Computer-Assisted Intervention, 2005

2004
Hybrid tracking system for flexible endoscopes.
Proceedings of the Medical Imaging 2004: Visualization, 2004

Automatic calibration of an optical see-through head-mounted display for augmented reality applications in computer-assisted interventions.
Proceedings of the Medical Imaging 2004: Visualization, 2004

Accuracy of the transfer of a preoperative plan from stereolithographic skull models to the patient.
Proceedings of the CARS 2004. Computer Assisted Radiology and Surgery. Proceedings of the 18th International Congress and Exhibition, 2004

Evaluation of a robotic targeting device for interventional radiology.
Proceedings of the CARS 2004. Computer Assisted Radiology and Surgery. Proceedings of the 18th International Congress and Exhibition, 2004

2003
Robotic guidance for percutaneous interventions.
Adv. Robotics, 2003

Navigation system for flexible endoscopes.
Proceedings of the Medical Imaging 2003: Visualization, 2003

Calibration of an optical see-through head-mounted display with variable zoom and focus for applications in computer-assisted interventions.
Proceedings of the Medical Imaging 2003: Visualization, 2003

Interactive localisator for percutaneous interventions.
Proceedings of the CARS 2003. Computer Assisted Radiology and Surgery. Proceedings of the 17th International Congress and Exhibition, 2003

2002
A Head-Mounted Operating Binocular for Augmented Reality Visualization in Medicine - Design and Initial Evaluation.
IEEE Trans. Medical Imaging, 2002

Laboratory assessment of a miniature electromagnetic tracker.
Proceedings of the Medical Imaging 2002: Visualization, 2002

PC-based control unit for a head-mounted operating microscope for augmented-reality visualization in surgical navigation.
Proceedings of the Medical Imaging 2002: Visualization, 2002

Stereoscopic visualization in the varioscope AR: a see-through head-mounted display for surgical navigation.
Proceedings of the Medical Imaging 2002: Visualization, 2002

The Control Unit for a Head Mounted Operating Microscope Used for Augmented Reality Visualization in Computer Aided Sugery.
Proceedings of the 2002 IEEE / ACM International Symposium on Mixed and Augmented Reality (ISMAR 2002), 30 September, 2002

2001
Calibration of projection parameters in the varioscope AR, a head-mounted display for augmented-reality visualization in image-guided therapy.
Proceedings of the Medical Imaging 2001: Visualization, 2001

Current Status of the Varioscope AR, a Head-Mounted Operating Microscope for Computer-Aided Surgery.
Proceedings of the 4th International Symposium on Augmented Reality (ISAR 2001), 2001

Fusion of MR and CT scans of the pelvis in cases of malignant bone tumors.
Proceedings of the CARS 2001. Computer Assisted Radiology and Surgery. Proceedings of the 15th International Congress and Exhibition, 2001

Calibration of a head-mounted operating microscope for augmented reality visualization in CAS.
Proceedings of the CARS 2001. Computer Assisted Radiology and Surgery. Proceedings of the 15th International Congress and Exhibition, 2001

2000
Accuracy of a Navigation System for Computer-Aided Oral Implantology.
Proceedings of the Medical Image Computing and Computer-Assisted Intervention, 2000

The Varioscope AR - A Head-Monted Operating Microscope for Augmented Reality.
Proceedings of the Medical Image Computing and Computer-Assisted Intervention, 2000


  Loading...